Comfort Nurse Call System
The ZKR Comfort series provide a structure for voice communication platforms within the ZKR product family. The system is designed to provide high level of communication between patients and nurses. It is also possible to integrate functions such as a room lightning, TV control, window blinds, and temperature from the handset as well as voice communication through Comfort series products between patient and nurse, or even external phone calls. Voice recordings of conversations between patient and staff or staff and other staff may be stored in the system for review by the hospital to improve quality of service. External phone calls can be tracked and billed to patients.
Comfort VoIP 10'' Room Control Unit
The Comfort Room Control Unit ensures communication between the Nurse Control Panel and the call units in patient rooms. This unit is suitable for surface montage. The unit supports up to 6 Call Units by default, and features a 10” touchscreen and a built-in Mifare card reader, which nurses use to verify their identity when responding to calls. All cards read by the unit are checked for authorization.The Room Control Unit can be used to initiate and terminate emergency code calls (Code Blue-Cardiac Arrest etc.), assist calls, and consultation calls. It allows routine controls the staff to use their cards to log into the room without an active call. The unit logs all activities to the server with timestamps and ID information. If the server connection is interrupted, the Room Control Unit will independently log up to 99 calls until server connection is reestablished. On the Comfort VoIP Room Control Unit, you can make voice calls with other SIP devices on the system. PoE (Power Over Ethernet) or 110-240 V VoIP Full Duplex SIP Conference Call Internal and External Call (with tracking system for billing) Built-in Mifare card Reader Timer/Stopwatch Menu option for personalized task lists based on personnel ID Can display hospital advertisements or other videos Can display educational videos for specific healthcare procedures
Versatile Plus 5'' Room Control unit
This device ensures communication between Nurse Control Panel and Call Units. It is suitable for both surface and flush montage. It features a 5” touchscreen and built-in RFID card reader, which nurses use to verify their identity when responding to calls. All cards read by the unit are checked for authorization. The Room Control Unit can be used to initiate and terminate emergency code calls (Code Blue-Cardiac Arrest etc.), assist calls, consultation calls, and voice calls to the Nurse Control Panel. It allows routine controls the staff to use their cards to log into the room without an active call. The unit logs all activities to the server with timestamps and ID information. If the server connection is interrupted, the Room Control Unit will independently log up to 99 calls until server connection is reestablished.
Comfort VoIP Patient Handset
With voice communication, patients can speak directly to the nurses assigned to them. This system allows hospital staff to save time on service, prioritize critical cases, and comfort patients through voice communication. Thanks to the ZKR Comfort Nurse Call System, all conversations between hospital personnel and patients can be recorded, giving opportunities for quality control. Evaluation of nurse performance can be displayed as a graph on the server interface. The Comfort VoIP Handset is easy to use. Patients can press the button labeled “Nurse Call” when they wish to send a regular nurse call signal, or they can press the large call button when they want to speak with the nurse assigned to them. The product is user-friendly, ergonomic, and hygienic. Using intelligent controls, patients can make internal and external phone calls with automatic billing. ZKR Comfort Nurse Call Systems can integrate as PBX analog, digital, and VoIP with any SIP-based brands. • PoE (Power Over Ethernet) • PBX • Full duplex • SIP protocol • Conference call • Function control within the room through Building Management System integration (such as lighting or window blinds) • TV channel and volume control • Internal and external call (with tracking system for billing)
Pro Patient Handset
The Pro Patient Handset allows the patient’s condition to be reported quickly to hospital staff in an emergency situation. Easy-to-clean, responsive membrane keypad Works though connection to Bedside Call Unit TV control options (Channel and Volume) EL lights allow visibility in the dark Clearly labeled function buttons can control room lighting, reading lamp, window blinds, etc.
Bedside Call Unit
The Bedside Call Unit is used in patient rooms. There are backlit call and cancel buttons on the unit. In an emergency, a patient uses the call button to make an emergency call which appears as an alert on the Nurse Control Panel. Typical locations for this unit are on thewalls of patient rooms and living areas. Handsets work through connection to this unit via RJ45 port on the front Can be flush mounted and has an ergonomic design RJ45 socket on the back provides easy installation Made of high quality PC-ABS-FR Raw Materials Call and Reset buttons are backlit and easy to notice in the dark
Pull-cord Call Unit
The Pull-cord Call Unit is used in patient bathrooms or similar areas. There is a backlit cancel button and an emergency call pull-cord on the unit. In an emergency, the patient makes an emergency call by pulling the cord. This appears as a WC Emergency Call on the Nurse Control Panel. The system gives priority to WC Emergency calls and they appear before regular Nurse Calls.
Over Door Light
The Over Door Light is located above the patient room door in the corridor. Its half-sphere shape makes it easily noticeable from any angle of view. The Over Door Light can indicate the call status of the room with up to 7 different colors (red, green blue, cyan, yellow, magenta, and white). It has very low energy consumption with environment-friendly LEDs. It is flush mounted by standard, but a surface montage box can be provided if necessary.
Application Server M30-M250
The server controls the operation of the Comfort, Versatile Plus, Versatile, and Air Plus (optional) systems used in hospitals. The server provides log reporting through a web interface and enables integration with other systems used throughout the building. Our servers have a Linux-based robust and reliable infrastructure Troubleshooting and error notification of all system devices Linux Operating System Voice Record Module Integrations Integration with WiFi mobile phones Integration with DECT telephones Integration with pagers Integration with PBX and ability to start emergency codes (such as 1111, 2222, 3333) IP, PRI, BRI, Analog Connection Integration with Fire Alarm Systems (Modbus, Bacnet, Special TCP connection types) Integration with CCTV Systems (Serial Port, Special TCP connection types) Integration with RFID Systems (Web service, Special TCP connection types) Integration with Hospital Information System Integration with Lighting Automation
Application Server M500- M1000
The server controls the operation of the Comfort, Versatile Plus, Versatile, and Air Plus (optional) systems used in hospitals. The server provides log reporting through a web interface and enables integration with other systems used throughout the building. Our servers have a Linux-based robust and reliable infrastructure Troubleshooting and error notification of all system devices Linux Operating System Voice Record Module Fully redundant structure Integrations Integration with WiFi mobile phones Integration with DECT telephones Integration with pagers Integration with PBX and ability to start emergency codes (such as 1111, 2222, 3333) IP, PRI, BRI, Analog Connection Integration with Fire Alarm Systems (Modbus, Bacnet, Special TCP connection types) Integration with CCTV Systems (Serial Port, Special TCP connection types) Integration with RFID Systems (Web service, Special TCP connection types) Integration with Hospital Information System Integration with Lighting Automation
Code Blue Unit
The Code Blue Unit is mounted on the wall as needed in the hospital. There are backlit call and code blue buttons on the unit. The call button may be pressed to initiate a nurse call which appears as an alert on the Nurse Control Panel. The code blue button may be pressed to start a Code Blue call. This button can also be configured as an assist call button.
Custodial Cell Call Unit
The Custodial Cell Call Unit is flush mounted on the walls of prisoner cells, psychiatric units or similar areas. There are nurse call and call termination buttons on it. It has an aesthetic and durable structure. Flush montage to prevent disassembly RJ45 socket allows easy installation Made of stainless steel Raw Material Vandal-proof, IK-10 certified in structure for use in psychiatric clinics and prisons
Function Control Module
Enables on/off control for two different functions within the room (such as reading lamp or window blinds) from the patient handset. One Function Control Module must be installed per Patient Handset, connected between the Room Control Unit and the Bedside Call Unit via its two RJ45 ports (in/out), or connected to a Call Unit port on the Room Control Unit by itself. The lamps take orders from the Room Control Unit so they must be assigned to the handset which will give them orders. This process takes place after the Call Units are given addresses.
Text Panel
The Text Panel is a scrolling 15-character dot matrix screen. It works with TCP-IP on the network, displays the calls as text, and gives audio alerts. Based on preference it can be set to display only specific types of calls. It works with 110-240 V.
Central Monitoring Software
The ZKR Central Monitoring Software is a web-based monitor that observes all activities such as nurse calls, code blue (and any custom emergency codes), assist calls, and nurse presences throughout the hospital. It can show picture IDs of personnel that are present in patient rooms. Different parameters (call type, department, and floor info) can be filtered based on needs. In this way, the focus of health personnel can be directed and reaction and intervention times can be minimized.