Versatile Nurse Call System
ZKR Versatile System is an IP based product family. It consists of touchscreen Room Control Units with built in Mifare card reader, bedside call units, patient handsets, pull-cord call units and over door lights to go above patient room doors. The calls made from the rooms can be seen on Nurse Control Panels as well as pagers, DECT phones, or Android-based mobile phones with the appropriate integrations. With the system being IP-based, management software can control the operation and stability of the equipment connected to it from start to finish. In the case of malfunction, a technical staff defined in the system can get notified immediately. The Versatile family is not just a nurse call system; it is a communication platform that gives you added value. It is a structure that can grow and develop with you in line with your needs. Integration of the system with the Hospital Information System (HIS) in the hospital is very easy. This integration is very effective in reporting to hospital management and upgrading service quality. Thanks to this integration, the critical information of the calling patient can also be sent to the relevant staff at the relevant times.
Versatile 4.3'' Room Control Unit
This unit ensures communication between the Nurse Control Panel and the Call Units. It is flush mounted. It has a 4.3’’ touchscreen and supports up to 8 call units. This unit can be used to initiate emergency code calls, assist calls, and consultation calls with Mifare card authorization.
Pro Patient Handset
The Pro Patient Handset allows the patient’s condition to be reported quickly to hospital staff in an emergency situation. Easy-to-clean, responsive membrane keypad Works though connection to Bedside Call Unit TV control options (Channel and Volume) EL lights allow visibility in the dark Clearly labeled function buttons can control room lighting, reading lamp, window blinds, etc.
Basic Patient Handset
The Basic Patient Handset allows the patient’s condition to be reported quickly to the hospital staff in an emergency situation. Easy to use Works though connection to bedside call unit LED back lights allow easy use in the dark LEDs stay lit when there is an active call until a nurse responds
Bedside Call Unit
The Bedside Call Unit is used in patient rooms. There are backlit call and cancel buttons on the unit. In an emergency, a patient uses the call button to make an emergency call which appears as an alert on the Nurse Control Panel. Typical locations for this unit are on the walls of patient rooms and living areas. Handsets work through connection to this unit via RJ45 port on the front Can be flush mounted and has an ergonomic design RJ45 socket on the back provides easy installation Made of high quality PC-ABS-FR Raw Materials Call and Reset buttons are backlit and easy to notice in the dark
Pull-cord Call Unit
The Pull-cord Call Unit is used in patient bathrooms or similar areas. There is a backlit cancel button and an emergency call pull-cord on the unit. In an emergency, the patient makes an emergency call by pulling the cord. This appears as a WC Emergency Call on the Nurse Control Panel. The system gives priority to WC Emergency calls and they appear before regular Nurse Calls.
Over Door Light
The Over Door Light is located above the patient room door in the corridor. Its half-sphere shape makes it easily noticeable from any angle of view. The Over Door Light can indicate the call status of the room with up to 7 different colors (red, green blue, cyan, yellow, magenta, and white). It has very low energy consumption with environment-friendly LEDs. It is flush mounted by standard, but a surface montage box can be provided if necessary.
Custodial Cell Call Unit
The Custodial Cell Call Unit is flush mounted on the walls of prisoner cells, psychiatric units or similar areas. There are nurse call and call termination buttons on it. It has an aesthetic and durable structure. Flush montage to prevent disassembly RJ45 socket allows easy installation Made of stainless steel Raw Material Vandal-proof, IK-10 certified in structure for use in psychiatric clinics and prisons
Code Blue Unit
The Code Blue Unit is mounted on the wall as needed in the hospital. There are backlit call and code blue buttons on the unit. The call button may be pressed to initiate a nurse call which appears as an alert on the Nurse Control Panel. The code blue button may be pressed to start a Code Blue call. This button can also be configured as an assist call button.
Versatile 18.5'' Nurse Control Panel
When a call is made, a text notification will appear on screen indicating the type and origin of the call, accompanied by an audio alert. The system uses call type priority while displaying notifications. Nurse calls, emergency calls, WC calls and nurse presences can be tracked on the panel simultaneously. The connectivity between units is maintained by a LAN. There is no limit on the number of rooms that can be connected to the Nurse Panel. All activities passing through the system are logged and can be reported in detail. 99.9% stable Linux-based OS Reliable database structure with MySQL Incoming calls are shown in order of priority Customizable audio alerts On screen real-time analysis of calls received and system error messages Text communication between Nurse Panels Call-forwarding to other Nurse Panels with Night Service feature Can have customized room names on display and in logs
Function Control Module
Enables on/off control for two different functions within the room (such as reading lamp or window blinds) from the patient handset. One Function Control Module must be installed per Patient Handset, connected between the Room Control Unit and the Bedside Call Unit via its two RJ45 ports (in/out), or connected to a Call Unit port on the Room Control Unit by itself. The lamps take orders from the Room Control Unit so they must be assigned to the handset which will give them orders. This process takes place after the Call Units are given addresses.
Function Control Module
Enables on/off control for two different functions within the room (such as reading lamp or window blinds) from the patient handset. One Function Control Module must be installed per Patient Handset, connected between the Room Control Unit and the Bedside Call Unit via its two RJ45 ports (in/out), or connected to a Call Unit port on the Room Control Unit by itself. The lamps take orders from the Room Control Unit so they must be assigned to the handset which will give them orders. This process takes place after the Call Units are given addresses.
Application Server M30-M250
The server controls the operation of the Comfort, Versatile Plus, Versatile, and Air Plus (optional) systems used in hospitals. The server provides log reporting through a web interface and enables integration with other systems used throughout the building. Our servers have a Linux-based robust and reliable infrastructure Troubleshooting and error notification of all system devices Linux Operating System Integration with WiFi mobile phones and messaging Integration with DECT telephones Integration with pagers Integration with PBX and starting emergency codes (such as 1111, 2222, 3333) IP, PRI, BRI, Analog Connection Integration with Fire Alarm Systems (Modbus, Bacnet, Special TCP connection types) Integration with CCTV Systems (Serial Port, Special TCP connection types) Integration with RFID Systems (Web service, Special TCP connection types) Integration with Hospital Information System Integration with Lighting Automation
Auxiliary Alert Lamp with I/O
Designed to be used for situations where a separate lamp must be used for each bed in multi-bed areas. Light color can be 7 different hues based on call status. • 7 colors colors (red, green, blue, cyan, yellow, magenta, white) • Very low energy consumption thanks to environment-friendly LEDs • Made of high quality PC-ABS-FR Raw Materials
Text Panel
The Text Panel is a scrolling 15-character dot matrix screen. It works with TCP-IP on the network, displays the calls as text, and gives audio alerts. Based on preference it can be set to display only specific types of calls. It works with 110-240 V.